Shocking Batteries
As
the use of batteries with voltages in excess of 300 Volts becomes more
commonplace with the growing popularity of electric and hybrid electric
vehicles, there is a danger that the general public, so used to
relatively benign 12 Volt batteries, may underestimate the hazards
associated with higher voltage traction batteries. Electric shocks
account for about 1% of all fatal accidents, mostly to people who ought
to know better.
This page describes the dangers and outlines some safety precautions when working with high voltage batteries.
Electric Shock
A
physiologist may view the body as containing an electrical network,
passing tiny nerve signals around enabling us to do all those essential
things we like to do so much such as breathing, thinking and moving.
Its function can be severely disrupted by the presence of an extraneous
current. The body also contains a network of canals transporting oxygen
to the muscles and the brain in a salty solvent called blood which
incidentally provides a good conducting medium for electricity.
To the battery however, the body is an insulated skin bag containing electrolyte. See also nerve impulses.
Despite
its common use as an indicator of danger, and the implication in the
opening paragraph, voltage is not a reliable indicator of the severity
of an electric shock. The most important indicators are the actual
current which flows through the body and its duration, and even these
can lead to misleading conclusions because the physiological
consequences depend on the route the current takes through the body.
Current passing through the heart or the brain is infinitely more
damaging than current passing across a finger or the palm of the hand
caught between the terminals of a battery. A sustained current will
also do more damage than a short current pulse.
Physiological Consequences of Electric Shock
The table below outlines some of the effects of direct electrical currents passing through the body for a period of one second.
Important Notes: The
two tables on this page are compiled from a variety of sources and
although there is general agreement between the sources on the
magnitude of the causes and effects, the actual values are subject to
very wide variations. Obviously, it is not practical to perform tests
on human subjects to verify the levels at which shocks become fatal and
some data is derived test on animals. The values used are therefore
average or typical values which should be used for illustrative
purposes only.
Dangerous currents are shown in Red.
 |
Shocking Effects |
 |
Current (contact 1 second) |
Physiological Effect |
Less than 1mA |
No sensation |
1mA |
Threshold of feeling. Tingling sensation |
5mA |
Maximum harmless current |
8 -15 mA |
Mild shock
Start of muscular contraction.
No loss of muscular control |
15 -20 mA |
Painful shock
Sustained muscular contraction.
Can't let go of conductor |
20-50 mA |
Can't breathe. Paralysis of the chest muscles
Possibly Fatal |
50 - 100 mA |
Intense pain
Impaired breathing
Ventricular fibrillation
Possibly fatal - Fatal if continued |
100-200 mA |
Ventricular fibrillation
Probably fatal - Fatal if continued
Respiratory function continues |
Over 200 mA |
Sustained ventricular contractions followed by normal heart rythm (defibrillation)
Chest
muscles clamp the heart and stop it for the duration of the shock. This
also prevents ventricular fibrillation improving the chances of
survival, but other factors come into play.
Burns Temporary respiratory paralysis.
Possibly fatal - Fatal if continued |
Over 1 Amp |
Severe burns.
Internal organs burned.
Death
Survivable if vital organs not in current path - e.g. across a finger or hand |
|
Notes:
-
Low voltages do not mean low hazard.
-
Other things being equal the degree of injury is proportional to the length of time the body is in the circuit.
-
According to the IEEE Std. 80, the maximum safe duration of a shock can be determined by the formula
T
= 0.116/(E/R), where T is the time in seconds, E is the voltage and R,
the resistance of the person (assumed to be 1000 ohms).
For a 120V circuit the maximum shock duration = 0.116/(120V/1000) = 1 Second
For a 240V circuit the maximum shock duration = 0.116/(240V/1000) = 0.5 Second
- It
is extremely important to free a shock victim from
contact with the current as quickly as possible. The difference of a
few seconds in starting artificial respiration may spell life or death
to the victim. Don't give up unless the victim has been pronounced dead
by a doctor.
- Women tend to be more susceptible to electric currents than men
- Lower body weight increases the susceptibility to electric currents
- A shock from DC is more likely to freeze or stop the victim's heart.
- The
current range of 100 to 200 ma, is particularly dangerous because it is
almost certain to result in lethal ventricular fibrillation, the
shocking of the heart into a
useless flutter rather than a regular beat .
-
The
fibrillation threshold is a function of current over time. For example,
fibrillation will occur with 500mA over 0.2 seconds or 75mA over 0.5
seconds.
- AC
is more dangerous than DC causing more severe muscular contactions. AC
is also more likely to cause a victim's heart to fibrillate , which is
a more dangerous condition. Safe working thresholds are consequently
much lower for AC voltages.
- It is
easier to restart a stopped heart once the source of the electric shock
has been removed than it is to restore a normal beating rythm to a
fibrillrating heart. A heart that is in fibrillation cannot be restored
to normal by closed chest cardiac massage. Defibrillrators give the
heart a jolt of DC to stop fibrillation to allow the heart to restart
with a normal beat.
- Victims of a
high voltage shock usually respond better to artificial respiration
than do victims of a low voltage shock, probably because the higher
voltage and current clamps the heart and hence prevents fibrillation.
The chances of survival are good if the victim is given immediate
attention.
- Shock victims may
suffer heart trouble up to several hours after being shocked. The
danger of electric shock does not end after the immediate medical
attention.
- Don't expect a circuit breaker to protect you. They trip at 15 Amps.
Shocking Potential
While
the severity of the electric shock is mainly determined by the current,
the current in turn is influenced by numerous variables which make up
the resistance of the current path making it difficult to predict the
current which will flow from a given voltage. The two major components
of the resistance are, the resistance of the body between the points of
contact with the electrical circuit, and the contact resistance between
the body and the voltage source. In more detail the body resistance
depends on the length of the conducting path through the body and the
body weight. The contact resistance depends on whether the contact is
wet or dry, the area of the contact, the firmness of the grip or touch
of the electrical contact and whether there is any other insulation in
the path. Because of this wide variation in resistance and contact
duration, people have been known to survive shocks of 40 KV while
others have been killed by less than 50 Volts
The
following table shows the conditions which could lead to a serious
electric shock. It gives the body and contact resistances associated
with a variety of conditions and indicates the current which will flow
for different voltages. The table above outlines the consequences.
 |
Currents Resulting From Electric Shocks |
 |
Circumstance
|
Resistance
(Ohms) |
Current mA |
50V |
100V |
250V |
500V |
Hand to ground (Rubber gloves or soles) |
20,000,000 |
0.002 |
0.005 |
0.01 |
0.02 |
Hand to ground (Dry hand, Leather soles) |
1,000,000 |
0.05 |
0.1 |
0.2 |
0.5 |
Dry skin |
500,000 |
0.1 |
0.2 |
0.5 |
1 |
Light touch (Dry) |
500,000 |
0.1 |
0.2 |
0.5 |
1 |
Hand gripping wire or metal tool (Dry) |
20,000 |
2.5 |
5 |
12.5 |
25 |
Light touch (Wet) |
10,000 |
5 |
10 |
25 |
50 |
Hand to ground (Wet hand, Damp leather sole) |
10,000 |
5 |
10 |
25 |
50 |
Hand gripping wire or metal tool (Wet) |
5,000 |
10 |
20 |
50 |
100 |
Hand to Hand (Damp) |
1500 |
33.3 |
66.6 |
166 |
333 |
Wet skin |
1000 |
50 |
100 |
250 |
500 |
Across human body |
1000 |
50 |
100 |
250 |
500 |
Hand to foot, Hand to hand (Excluding skin) |
500 |
100 |
200 |
500 |
1000 |
Between the ears , Across a finger (Excuding skin) |
100 |
500 |
1000 |
2500 |
5000 |
Punctured skin with cuts, abrasions or burns caused by the electric current itself |
No resistance |
|
|
|
|
|
Notes:
- The skin is a most important insulator.
- There are huge variations in contact resistance.
- Working with minor wounds to the hands seriously increases the risk of shock.
- Once a shock has been initiated, the resulting electrical burn can puncture the skin and increase the shocking current.
- Rings, bracelets and other jewellery decrease the contact resistance to the body and increase the potential for electric shock.
- Use only one hand (keeping one hand in your pocket) while
working on high voltage circuits avoids the risk of the body becoming part of the circuit.
- Risks
can be minimised by using insulated hand tools (pliers, screwdrivers,
spanners etc.) and by wearing rubber gloves and shoes.
Safe Working Practices
There
are many published standards for safe working practices on AC power
circuits including those from the HSE in the UK and OSHA in the USA.
See the section on Standards.
The following are additional recommendations relevant to working on battery circuits.
- The usual safe working voltage threshold for working on batteries is 50 volts DC.
- Avoid working on a fully charged battery. Arrange for batteries to be discharged wherever possible.
- Use a voltmeter to check whether the battery is charged before starting work.
- Check that any capacitors associated with the battery circuit are discharged.
- Cover exposed terminals where possible to avoid touching or dropping tools onto them.
- When
starting work on a supposedly dead circuit make contact first with the
back of one hand, so that if a shock should occur, the muscle reaction
will not cause the hand to grip the conductor.
- See also the notes above.
Treat high power batteries with the same respect you would give to AC mains voltages.
See also Short Circuits and their Consequences
History
|